EVALUASI KINERJA DISIPASI ENERGI LINK PENDEK PADA ECCENTRIC BRACED FRAME DENGAN SOFTWARE ABAQUS

REBHUNG, DAVID KENICHI (2018) EVALUASI KINERJA DISIPASI ENERGI LINK PENDEK PADA ECCENTRIC BRACED FRAME DENGAN SOFTWARE ABAQUS. S2 thesis, UAJY.

[img]
Preview
Text (HALAMAN JUDUL)
MTS025510.pdf

Download (1MB) | Preview
[img]
Preview
Text (BAB I)
MTS025511.pdf

Download (158kB) | Preview
[img]
Preview
Text (BAB II)
MTS025512.pdf

Download (146kB) | Preview
[img]
Preview
Text (BAB III)
MTS025513.pdf

Download (1MB) | Preview
[img] Text (BAB IV)
MTS025514.pdf
Restricted to Registered users only

Download (173kB)
[img] Text (BAB V)
MTS025515.pdf
Restricted to Registered users only

Download (2MB)
[img]
Preview
Text (BAB VI)
MTS025516.pdf

Download (788kB) | Preview

Abstract

Indonesia is among the earthquake prone countries with the largest deaths percentage caused by building collapse. On the skeletal system of earthquake resistant structure, based on Seismic Provisions for Structural Steel Buildings (AISC) 2010, a performance evaluation of energy dissipation to link beam (e) in the Eccentrically Braced Frames (EBF) type K-braces system has been done, since the link beam acts as a damper withstand shear and bending forces due to earthquake loads. Evaluation was done on short link beam (e ≤ 1,6Mp/Vp) vertical web stiffener of 20 story EBF structure located in Padang -Sumatera Barat, by studying the performance of short link vertical web stiffener blocks due to cyclic loading in the form of displacement at a certain amplitude of the initial yield velocity (Δy) varying by 1Δy, 2Δy, 5Δy, and 10Δy considered to represent extreme seismic loads. The building was designed according to ANSI/AISC 2010 using software Extended Three Dimensional Analysis of Building Systems (ETABS) version 2016, with an earthquake load in accordance with SNI 1726:2012 which refers to ASCE/SEI 7-10. The results showed that dissipation energy of short beam link vertical web stiffener with loading below maximum load limit, on increasing loading (1Δy, 2Δy, dan 5Δy), the greater the cyclic load increase the percentage of energy decrease increase, and the number of plastic cycles before the impedance decreases, while the constant loading (10Δy) has a relatively same decrease in energy per cycle and increased number of plastic cycles before the collapse.

Item Type: Thesis (S2)
Uncontrolled Keywords: Eccentrically Braced Frames tipe K-braces, link pendek berpengaku badan vertikal, pembebanan siklik, dan disipasi energi.
Subjects: Magister Teknik Sipil > Struktur
Divisions: Pasca Sarjana > Magister Teknik Sipil
Depositing User: Editor UAJY
Date Deposited: 19 Feb 2019 03:21
Last Modified: 19 Feb 2019 03:21
URI: http://e-journal.uajy.ac.id/id/eprint/16780

Actions (login required)

View Item View Item