Abstract

Indonesia is located on three major tectonic plates, which are Indo-Australia plate, Eurasia plate and Pacific plate. Indonesia is also passed by ring of fire volcanic mountain range. As the result, several area in Indonesia is prone to both volcanic and seismic earthquakes. As example earthquakes that occurred in Yogyakarta in 2006 resulted in major damages. When earthquake occurs, the building resists the force and displacement. When the force or displacement exceed the limits the damage occurs to the building to certain extend. When building is designed to respond elastically with no ductility, it may fail to the ground motion due the force is greater than building strength. On the other hand, if the building designed with ductility, it will be damaged but still able to withstand severe ground motion without failure. Contrary to previous method, base isolation reduces the response of the structure by separate and reducing the ground motion from the earth. Universitas Atma Jaya Yogyakarta (UAJY) is located in an earthquake prone region. This final project attempts to design the base isolation system and compare the structure’s respose on UAJY’s library building. The method used in the design will be using design procedure proposed by MCEER technical report on Property Modification Factor for Seismic Isolator: Design Guidance for Building, which based on 14 November draft of AISC 7-2016. The system final layout is comprised of 18 Lead Rubber Bearing and 33 Natural Rubber Bearing. The modelling of the structure will be done on ETABS version 9.6 and the dynamic analysis on ETABS was conducted using the El Centro 1940 earthquake time history data. The application of TMD on the structure successfully increase the displacement and reduce story drift, acceleration and the story shear of the structure. Base Isolation Structure achieved a total of 70.9% of increase in total displacement in the structure. The largest displacement occurs on the base floor, which have displaced 21.63 cm from initial point. Therefore, the actual story drift of the structure is decrease by average of 70.4%. The displacement makes the natural period of the structure increased to 2.34 s from 1.007 s. This lead to decrease of acceleration in top-story by 70.3% and decrease of story shear force by average 68.4 %. From the analysis of the data output it can be concluded that the use of base isolation system will have significant impact on response of the structure.

Item Type: Thesis (S1)
Uncontrolled Keywords: Base Isolator System, El Centro 1940 earthquake time history, ETABS, LRB, Mass Ratio, MCEER Seismic Isolator Design Guidance, NRB
Subjects: Civil Engineering > Structure
Divisions: Fakultas Teknik > Teknik Sipil Internasional
Depositing User: Editor UAJY
Date Deposited: 09 May 2017 08:27
Last Modified: 09 May 2017 08:27
URI: http://e-journal.uajy.ac.id/id/eprint/11708

Actions (login required)

View Item View Item