THE EFFECT OF BOND ON RETROFITTING USING NEW CONCRETE LAYERS

Willy, . (2020) THE EFFECT OF BOND ON RETROFITTING USING NEW CONCRETE LAYERS. S1 thesis, Universitas Atma Jaya Yogyakarta.

[img]
Preview
Text (Willy)
161316472_Chap 0.pdf

Download (779kB) | Preview
[img]
Preview
Text
161316472_Chap 1.pdf

Download (236kB) | Preview
[img]
Preview
Text
161316472_Chap 2.pdf

Download (523kB) | Preview
[img] Text
161316472_Chap 3.pdf
Restricted to Registered users only

Download (1MB)
[img] Text
161316472_Chap 4.pdf
Restricted to Registered users only

Download (273kB)
[img] Text
161316472_Chap 5.pdf
Restricted to Registered users only

Download (521kB)
[img]
Preview
Text
161316472_Chap 6.pdf

Download (272kB) | Preview

Abstract

The retrofitting process of the damaged structure members is needed in order to achieve the good performance of the structure members. One of the methods to do the retrofitting process is called jacketing technique. The common jacketing technique consists of concrete, steel, and FRP jacketing. Although those three types of jacketing give some benefits, there are also some drawback. The use of UHPC jacketing can be considered to overcome the drawback of those three-jacketing technique. In order to retrofit by using jacketing technique, the bond strength between the substrate concrete and overlay concrete must be well considered. The bond strength can be controlled by some parameters such as substrate surface condition, curing condition, mechanical connectors and the use of bonding agent. The best method for the parameters is exposing the aggregate and saturated condition, normal and water curing, higher concrete substrate strength and 28 days age of UHPC, and the use of bonding agent on the smooth surface and the absence of the bonding agent on the rough surface, respectively. Besides that, the use of mechanical connectors can be considered to improve the bond strength. Some consideration such as the diameter of connectors of 22 mm, the height of the connectors of 100 mm, UHPC thickness of 50 mm, and the use of fiber and longitudinal steel rebars are proven to enhance the bond strength and achieve the ductility demand. Furthermore, the parameters mentioned above are proven to enhance the bond strength at the interface between substrate concrete and overlay concrete.

Item Type: Thesis (S1)
Uncontrolled Keywords: Concrete, Retrofitting, Bond Strength, Mechanical Connectors
Subjects: Civil Engineering > Structure
Divisions: Fakultas Teknik > Teknik Sipil Internasional
Depositing User: Editor 3 uajy
Date Deposited: 29 Sep 2022 08:09
Last Modified: 29 Sep 2022 08:09
URI: http://e-journal.uajy.ac.id/id/eprint/27509

Actions (login required)

View Item View Item