PARAHITA, AMBROSIUS BRIAN RAHARDIAN (2011) CORELATION OF CBR LABORATORY TEST AND DYNAMIC CONE PENETROMETER TEST (Selokan Mataram Road Maguwoharjo – Babarsari). S1 thesis, UNSPECIFIED.
|
Text (Cover Title)
0TS12508.pdf Download (22MB) | Preview |
|
|
Text (Chapter I)
1TS12508.pdf Download (128kB) | Preview |
|
|
Text (Chapter II)
2TS12508.pdf Download (131kB) | Preview |
|
Text (Chapter III)
3TS12508.pdf Restricted to Registered users only Download (6MB) |
||
Text (Chapter IV)
4TS12508.pdf Restricted to Registered users only Download (39MB) |
||
Text (Chapter V)
5TS12508.pdf Restricted to Registered users only Download (1MB) |
||
|
Text (Chapter VI)
6TS12508.pdf Download (145kB) | Preview |
Abstract
The use of Dynamic Cone Penetrometer resulted in an estimated ratio of soil strength. Dynamic cone penetrometer can also be used as an indicator of changes in soil moisture in situ testing in accordance through the soil profile. Research in this study is laboratory test at the Department of Civil Engineering, Faculty of Engineering, University of Atma Jaya Yogyakarta and DCP test field (along the Selokan Mataram Road Maguwo - Babarsari to obtain a minimum of 15 samples). The purpose of this research is to find the correlation value of CBR (California Bearing Ratio) and DCP (Dynamic Cone Penetrometer). The research divided into two tests, first for the DCP test in order to find the DCP value (mm / blow). The second test is CBR laboratory test to find the CBR value. CBR and DCP values are plotted on a graph and then look for the value of its correlation with a linear regression methods. After correlation CBR - DCP resulting equation Log CBR = 1.175494 - 0.011362 Log (DCP), the CBR value (%) of each DCP test locations can be searched by this equation. CBR and DCP correlation values in this study at location 1 close to the correlation of previous studies by NCDOT (1998) with the equation log (CBR) = 2.60 – 1.07 log (DCP), and at location 2 to 10 close to the correlation of previous studies by Livneh et . al. (1992) with the equation log (CBR) = 2.45 – 1.12 log (DCP). From the correlation obtained, laboratory CBR value can be correlated with value of DCP in the field. From this correlation obtained the DCP test value every location at the field closed to the CBR laboratory value with the real condition.
Item Type: | Thesis (S1) |
---|---|
Subjects: | Civil Engineering > Structure |
Divisions: | Fakultas Teknik > Teknik Sipil Internasional |
Depositing User: | Editor UAJY |
Date Deposited: | 03 Jun 2013 11:30 |
Last Modified: | 03 Jun 2013 11:30 |
URI: | http://e-journal.uajy.ac.id/id/eprint/2019 |
Actions (login required)
View Item |